82-253290 E01 March 2008
TEST SYSTEM FOR CONDUCTED AND
RADIATED IMMUNITY
NSG 4070
The NSG 4070, successor of the NSG 2070, is a multifunctional EMC immunity test system. Its large fre-
quency range from 9 kHz to 1 GHz and its modular set-up using internal or external amplifi ers enable a
large variety of applications including tests according to IEC 61000-4-6, various BCI applications as well as
signal generator and power meter for test systems as per IEC 61000-4-3, IEC 61000-4-20, IEC 61000-4-21
and many other applications. The powerful and easy to use fi rmware makes the NSG 4070 independent
from an external PC and control software, however it can also be remote controlled for system operation.
A state-of-the-art data transfer of test and measurement data for documentation is provided by USB
stick to be plugged into the front panel.
External access to
signal generator output
and power amplifier
input and output
User port for 4 TTL
inputs and 4 TTL outputs
and supply voltages for
individual monitoring
and control applications
3 power meter
inputs
Analog, digital and
optical monitoring
inputs for extensive
EUT monitoring
options
5.7“ color display,
easy to use firmware
10 MHz reference for
synchronisation, Trigger
input for external con-
trol of measurement
routines
Hard keys for
important functions
Remote control via
RS232, LAN or USB
Integrated signal generator 9 kHz to
1 GHz
3 power meter inputs 9 kHz to
1 GHz
Integrated power amplifier module
for different applications
Multiple EUT monitoring options
5,7“ TFT color display
Internal, menu-based control soft-
ware
Basic remote control software and
report generator included
NSG 4070
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - RADIATED IMMUNITY

82-253290 E01 March 2008TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITYNSG 4070The NSG 4070, successor of the NSG 2070, is a multifunctional EMC immun

Page 2

NSG 4070 datasheet10TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITYNSG 4070Application for automotive BCI, calibration set-up (power requirements and

Page 3

82-253290 E01 March 200811TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITYNSG 4070Application for IEC/EN 61000-4-3 up to 1 GHz (power requirements and

Page 4

NSG 4070 datasheet12TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITYNSG 4070Teseq GmbHLandsberger Str. 255 · 12623 Berlin · GermanyT + 49 30 56 59 88 3

Page 5

NSG 4070 datasheet2TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITYNSG 4070Technical specificationsGeneratorRF Frequency range: 9 kHz – 1 GHzResolutio

Page 6

82-253290 E01 March 20083TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITYNSG 4070Nominal output power: 20 W 30 W 75 WFrequency range: 150 kHz – 230 MHz

Page 7

NSG 4070 datasheet4TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITYNSG 4070Test and measurement routinesFirmware: Generator modeFirmware: Immunity mode

Page 8

82-253290 E01 March 20085TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITYNSG 4070Windows softwareWindows software: Generator modeWindows software: Immu

Page 9

NSG 4070 datasheet6TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITYNSG 4070Analog portsDigital portsFront panel Generator output: N socket 50 Ω, 9 kH

Page 10 - NSG 4070

82-253290 E01 March 20087TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITYNSG 4070Power supplyPower supply unit 110 / 230 VAC 50 / 60 Hzautorangingrecom

Page 11

NSG 4070 datasheet8TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITYNSG 4070Application for IEC/EN 61000-4-6, calibration set-up with CDNApplication for

Page 12

82-253290 E01 March 20089TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITYNSG 4070Application for IEC/EN 61000-4-6, calibration set-up with current inje

Comments to this Manuals

No comments