This document describes the performance and
features of the Agilent Technologies 8720E family
of network analyzers. For more information about
these analyzers, please refer to the following
documents:
Agilent 8720E family network analyzers overview,
Agilent literature number 5968-5161E
Agilent 8720E family network analyzers configura-
tion guide, Agilent literature number 5968-5162E
Agilent 8720E Family
Microwave Vector Network
Analyzers
Data Sheet
8719ET Transmission/reflection vector network analyzer
8719ES S-Parameter vector network analyzer
50 MHz to 13.5 GHz
8720ET Transmission/reflection vector network analyzer
8720ES S-parameter vector network analyzer
50 MHz to 20 GHz
8722ET Transmission/reflection vector network analyzer
8722ES S-parameter vector network analyzer
50 MHz to 40 GHz
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - Analyzers

This document describes the performance and features of the Agilent Technologies 8720E familyof network analyzers. For more information aboutthese ana

Page 2 - Table of Contents

10Agilent 8719ES or 8720ES with Option 007 or 085Calibration kit: 85052B 3.5-mm with sliding loadsCables: 85131F 3.5-mm flexible cable setIF bandwidth

Page 3 - Measurement uncertainty

11Agilent 8719ES or 8720ES with Option 007 or 085Calibration kit: 85052D 3.5-mm with fixed loadsCables: 85131F 3.5-mm flexible cable setIF bandwidth:

Page 4 - System performance

12Agilent 8722ES with Option 007 or 085Calibration kit: 85056A 2.4-mm with sliding loadsCables: 85133F 2.4-mm flexible cable setIF bandwidth: 10 HzAve

Page 5 - 2. 3 dB less with Option 012

13Agilent 8722ES with Option 007 or 085Calibration kit: 85056D 2.4-mm with fixed loadsCables: 85133F 2.4-mm flexible cable setIF bandwidth: 10 HzAvera

Page 6

Agilent 8719ET and 8720ET with 3.5 mm test portsStandard or Option 004Calibration kit: 85052B 3.5-mm with sliding loads Cables: 85131F 3.5-mm flexible

Page 7

Agilent 8722ET with 2.4 mm test portsStandard or Option 004Calibration kit: 85056A 2.4-mm with sliding loads Cables: 85133F 2.4-mm flexible cable set

Page 8

16Agilent 8719ES, 8720ES, or 8722ES Option 012 Option 012 adds RF loops that provide direct accessto the A and B samplers in the port 1 and port 2rece

Page 9 - Switches

17Agilent 8719ES, 8720ES, and 8722ES Option 089Option 089 adds frequency offset mode, allowingthe receiver to be offset from the source frequency.This

Page 10 - System performance, continued

18Agilent 8719ES, 8720ES, and 8722ESDescription CodeFrequency Range8719ES 0.05 to 13.51 GHz S8720ES 0.05 to 20.05 GHz S8722ES 0.05 to 40.05 GHz SAccur

Page 11

19Agilent 8719ET, 8720ET, and 8722ETDescription CodeFrequencyRange8719ET 0.05 to 13.51 GHz S8720ET 0.05 to 20.05 GHz S8722ET 0.05 to 40.05 GHz SAccura

Page 12

34182021233031Table of ContentsDefinitions and test conditionsSystem performanceSpecifications and characteristicsMeasurement throughput summaryOption

Page 13

20Full frequency band sweep time (ms)1Number of PointsMeasurement 51 201 401 1601(Swept mode/Stepped mode)Single band sweep (10 to 12 GHz)Uncorrected

Page 14

21Agilent 8719ES, 8720ES, and 8722ES Agilent 8719ET, 8720ET, and 8722ETTime-domain (Option 010)With the time-domain option, data from transmis-sion or

Page 15

22GatingThe gating function can be used to selectivelyremove reflection or transmission time-domainresponses. In converting back to the frequencydomai

Page 16 - 2. 10 Hz IF BW

23Measurement capabilitiesNumber of display channelsFour display channels available.Number of measurement channels Two primary (independent) and two a

Page 17

24Internal source controlSweep limitsSet start/stop or center/span of the stimulusparameter (frequency, power, or time) directlythrough the source con

Page 18 - <–65 dBc T

25TRL*/LRM* calibrationCompensates for directivity, reflection, and trans-mission frequency response, and crosstalk in boththe forward and reverse dir

Page 19

26Display controlDisplay formatsSingle-channel, dual-channel overlay (both traceson one graticule), dual-channel split (each trace on separate graticu

Page 20

27Limit linesDefine test limit lines that appear on the displayfor go/no go testing. Lines may be any combinationof horizontal, sloping lines, or disc

Page 21 - Time-domain (Option 010)

28GPIB (remote) programmingInterfaceGPIB interface operates to IEEE 488-1978 and IEC625 standards and IEEE 728-1982 recommendedpractices.AddressingThe

Page 22 - Options, continued

29Rear panel connectors (continued)• GPIB This connector allows communication with compatible devices including external controllers, printers, plotte

Page 23 - System capabilities

3Specifications describe the instrument’s warrantedperformance after a half-hour warm-up and overthe temperature range of 23° C ± 3° C, unless otherwi

Page 24 - Calibration types available

30Agilent 85071C materials measurement softwareDescriptionThe 85071C software uses broadband S-parametermeasurements to determine the electromagneticp

Page 25 - Data averaging

31A wide range of accessories support the Agilent8720E family of network analyzers, including cali-bration kits, verification kits, cables, and adapte

Page 26 - Data hardcopy

32Economy calibration kitsInclude the open circuit, short circuit, and fixedtermination standards but not sliding terminationsor gauges. Gauges can be

Page 27 - Test sequences

33Test port return cable specificationsConnector Ttpe Frequency Length2Return Insertion loss Stabillty1, 2±Phase (Test port to device) (GHz) cm (i

Page 28 - General characteristics

34Test port adapter setsThe Agilent 85130 series test port adapter sets protect the test set port when connecting devicesto the test port. These adapt

Page 30

Agilent Technologies’ Test and Measurement Support, Services, and AssistanceAgilent Technologies aims to maximize the value you receive, while minimiz

Page 31 - Calibration kits

4Agilent 8719ES and 8720ES with 3.5 mm test portsStandard, Options 400, 0121, 089, or any combina-tion of these options. Calibration kit: 85052B, 3.5-

Page 32 - Test-port return cables

5Agilent 8722ES with 2.4 mm test portsStandard, Options 400, 0121, 089, or any combina-tion of these options.Calibration kit: 85056A, 2.4-mm with slid

Page 33

6Agilent 8719ES and 8720ES with 3.5 mm test portsStandard, Options 400, 0121, 089, or any combina-tion of these options.Calibration kit: 85052D, 3.5-m

Page 34 - Accessories, continued

7Agilent 8722ES with 2.4 mm test portsStandard, Options 400, 0121, 089, or any combina-tion of these options.Calibration kit: 85056D, 2.4-mm with broa

Page 35

8Agilent 8719ES Option 400, 8720ES Option 400,and 8722ES Option 400 with 3.5 mm test portsusing TRLIncludes instruments with Options 0121and/or 089. C

Page 36 - Agilent Email Updates

9Agilent 8719ES, 8720ES, and 8722ES Option 007Agilent 8719ES, 8720ES, and 8722ES Option 085Includes instruments with Options 0121and/or 089.Option 007