Atec Agilent-8753E User Manual

Browse online or download User Manual for Equipment Atec Agilent-8753E. Atec Agilent-8753E User Manual [es]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 25
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
The HP 8753E RF vector network analyzer provides
all the performance and productivity features to
simplify and speed your component measurements in the
30 kHz to 6 GHz frequency range. Its new processor
makes measurement and data-transfer speeds up to seven
times faster than the previous model. Overall throughput
is enhanced by new features such as simultaneous four
parameter display* and adapter-removal calibration. An
integrated, synthesized source provides up to 10 mW of
output power (100 mW for Option 011), 1 Hz frequency
resolution, and linear-frequency, log-frequency, list-
frequency, CW, and power sweep types. Three tuned
receivers allow independent power measurements or
simultaneous ratio measurements over a wide dynamic
range of 105 dB at 6 GHz (with Option 006 frequency
extension) or 110 dB at 3 GHz (standard). The integrated
test set allows you to measure transmission and reflection
characteristics of a device to 6 GHz, without a frequency
doubler.
The HP 8753E network analyzer features two independent
measurement channels. You can choose to display any
combination of reflection and transmission parameters,
in magnitude, phase, group-delay, Smith-chart, polar, SWR,
or time-domain formats. Softkeys let you quickly access
measurement functions, and you can view results in over-
lay or split-screen format on the LCD color display. A
VGA-compatible output has been added to drive larger
external monitors for optimum viewing.
*available Q298
HP 8753E maximizes versatility
and performance
Frequency range from 30 kHz to 3 GHz, or
optionally 6 GHz.
Built-in S-parameter test set provides complete
forward and reverse measurements, allowing you
to characterize your component with a single
connection.
50 and 75-ohm solutions.
Superb accuracy. Comprehensive calibration
guarantees accurate measurements. TRL*/LRM*
make calibration in noncoaxial environments easier
and more convenient.
Mixer testing. Quickly and easily characterize
frequency translating devices such as mixers.
Add swept harmonic measurements. Characterize
amplifier parameters — gain, 1 dB compression,
match — and 2nd and 3rd harmonic distortion with
the same test setup.
Built-in 3.5 inch floppy disk drive provides
convenient storage of instrument states and data.
Parallel and serial ports provide interfaces to
popular printers and plotters. The parallel port
can also be used as a general I/O bus, with user
controllable TTL inputs and outputs. Users can
also connect a DIN keyboard to speed up entry of
titles, labels, or file names, and for remote front
panel operation.
HP 8753E RF Vector
Network Analyzer
Technical Specifications
30 kHz to 3 GHz or 6 GHz
Page view 0
1 2 3 4 5 6 ... 24 25

Summary of Contents

Page 1 - Technical Specifications

The HP 8753E RF vector network analyzer provides all the performance and productivity features to simplify and speed your component measurements in th

Page 2 - Organization of data

10HP 8753E Option 011 specifications1. At 25˚ C ±5˚ C, relative to 0 dBm output power for the HP 8753E, +10 dBm output power for the HP 8753E Option 0

Page 3 - System performance summary

MeasurementNumber of display channelsTwo display channels available.Measurement parametersHP 8753E: S11, S21, S12, S22, A, B, R, A/R, B/R, A/B.Convers

Page 4

12HP 8753E supplemental characteristics, cont’d1. +8 dBm with Option 075.Sweep timeSet sweep time in seconds, minutes or hours. Minimumsweep time is d

Page 5

13HP 8753E supplemental characteristics, cont’d• Interpolated error correctionWith any type of accuracy enhancement applied, interpo-lated mode recal

Page 6

14HP 8753E supplemental characteristics, cont’dStorageInstrument stateUp to 31 instrument states can be stored internally orrecalled via the SAVE/RECA

Page 7

15HP 8753E supplemental characteristics, cont’dOffset valueSet the offset frequency value.Service menuSelect the desired service test, service diagnos

Page 8 - HP 8753E specifications

• Time domain rangeThe range over which the display is free of response repe-tition depends on the frequency span and the number ofpoints. Range, in n

Page 9

17HP 8753E supplemental characteristics, cont’dTransfer formatsBinary (internal 48-bit floating point complex format)ASCII 32- or 64-bit IEEE 754 floa

Page 10 - Harmonics (Option 002)

Internal memoryTypical data retention time with 3V, 1.2 Ah battery:At 25° C 11904 days (32.6 years) At 40° C 1244 days (3.4 years) At 70° C 250 days (

Page 11 - Source control

HP 85046A/B S-parameter test setsThe HP 85046A/B S-parameter test sets provide the capa-bility to measure reflection and transmission characteris-tics

Page 12 - Power meter calibration

2Definitions and test conditionsThis document provides two types of performance information:Specifications describe the instrument’s warranted perfor-

Page 13 - Display Control

20HP 8753E test set specifications, cont’dHP 85047A S-parameter test setThe HP 85047A S-parameter test set provides the capability to simultaneously m

Page 14 - System capabilities

Calibration kitsVector accuracy enhancement procedures require that thesystematic errors of the measurement system be character-ized by measuring know

Page 15 - Time domain (Option 010)

22HP 8753E accessories, cont’dHP 85039B type-F calibration kitContains a set of 75-ohm type-F standards to calibrate theHP 8753E and 75-ohm test set f

Page 16 - Remote programming

23HP 8753E accessories, cont’dOpt 001 type-N (m) on RF input type-N (f) on outputs Opt 002 type-N (f) on RF input precision 7-mm on outputs Dimensio

Page 17 - General characteristics

SpecificationsInput capacitance (at 500 MHz) <0.7 pF (nominal) Input resistance 1 Megohm (nominal) Bandwidth 300 kHz to 3 GHz Gain (at 500 MHz) 0

Page 18 - Environmental characteristics

For more information aboutHewlett-Packard test and measure-ment products, applications, ser-vices, and for a current sales officelisting, visit our we

Page 19 - Specifications HP 85046A(B)

3System performance summaryHP 8753E (50-ohm systems) 7-mm test ports1. 90 dB, 30 kHz to 50 kHz.2. 100 dB, 300 kHz to 16 MHz due to fixed spurs.3. Thes

Page 20

4System performance summaryHP 8753E (50-ohm systems) type-N test ports1. 90 dB, 30 kHz to 50 kHz.2. 100 dB, 300 kHz to 16 MHz due to fixed spurs.3. Th

Page 21 - HP 8753E accessories

5System performance summaryHP 8753E (50-ohm systems) 3.5-mm test ports1. 90 dB, 30 kHz to 50 kHz.2. 100 dB, 300 kHz to 16 MHz due to fixed spurs.3. Th

Page 22

6System performance summaryHP 8753E (75-ohm systems) type-N test ports1. 90 dB, 30 kHz to 50 kHz.2. 100 dB, 300 kHz to 16 MHz due to fixed spurs.3. Th

Page 23 - Specifications

7System performance summaryHP 8753E (75-ohm systems) type-F test ports1. 90 dB, 30 kHz to 50 kHz.2. 100 dB, 300 kHz to 16 MHz due to fixed spurs.3. Th

Page 24 - HP 8753E accessories, cont’d

8HP 8753E specifications1. At 25˚ C ±5˚ C, relative to 0 dBm output power for the HP 8753E, +10 dBm output power for the HP 8753E Option 011.2. Typica

Page 25

9HP 8753E specifications1. Typical performance.2. Typical below 300 kHz. 3. The HP 8753E source characteristics and measurement accuracy in this mode

Comments to this Manuals

No comments