E5071C ENA Network Analyzer • 9 kHz to 4.5/6.5/8.5 GHz • 100 kHz to 4.5/6.5/8.5 GHz (with bias tees) • 300 kHz to 14/20 GHz (with bias tees)E509

Page 2 - Table of Contents

10Table 6. Corrected system performance with 3.5 mm device connector type, 85093C electronic calibration (ECal) moduleNetwork analyzer: E5071CCalib

Page 3

11Option 2D5/2K5/4D5/4K5Table 7. Corrected system performance with 3.5 mm device connectors, 85052D calibration kit Network analyzer: E5071C Calibr

Page 4 - Boundary Conditions

12Table 8. Corrected system performance with 3.5 mm device connectors, N4691B electronic calibration (ECal) module Network analyzer: E5071CCalibrat

Page 5 - Corrected System Performance

13Uncorrected System PerformanceTable 9. Option 230/235/240/245/260/265/280/285/430/435/440/445/460/465/480/485User correction: OFF, system correction

Page 6

14Test Port Output (Source)Test port output frequencyTable 11. Option 230/235/240/245/260/265/280/285/430/435/440/ 445/460/465/480/485/2D5/2K5/4D5/4K5

Page 7 - 85032F calibration kit

15Test port output power1 Table 12. Option 230/235/240/245/260/265/280/285/430/435/440/ 445/460/465/480/485Description Specifi cation TypicalNominal po

Page 8

16Test port output power7 (continued)Table 13. Option 2D5/2K5/4D5/4K5Description Specifi cation TypicalNominal power (preset power) –5 dBmLevel accurac

Page 9 - 85033E calibration kit

17Test port output power6 (continued)Table 13. Option 2D5/2K5/4D5/4K5Description Specifi cation SPDMax leveled power3, 4 300 kHz to 1 MHz 1 MHz t

Page 10 - Specifi cation (dB)

18Test Port InputTest port input levelsTable 16. Option 230/235/240/245/260/265/280/285/430/435/440/ 445/460/465/480/485Description Specifi cation Typi

Page 11 - Uncertainty (Degrees)

19Test port input levels (continued) Table 17. Option 2D5/2K5/4D5/4K5Description Specifi cation TypicalMaximum test port input level300 kHz to 20 GHz +

Page 12

2Table of ContentsOptions ... 3De

Page 13 - 460/465/480/485

20Test port input (compression level)Table 18. Option 230/235/240/245/260/265/280/285/430/435/440/445/460/465/480/485Description Specifi cation SPDComp

Page 14 - Test Port Output (Source)

21Test port input (trace noise)Table 20. Option 230/235/240/245/260/265/280/285/430/435/440/ 445/460/465/480/485Description Specifi cation SPDTrace noi

Page 15 - Test port output power

22Test port input (trace noise) (continued)Table 21. Option 2D5/2K5/4D5/4K5Description Specifi cation SPDTrace noise magnitude1, 3300 kHz to 1 MHz (IFB

Page 16

23Test port input (stability)1Table 22. Option 230/235/240/245/260/265/280/285/430/435/440/ 445/460/465/480/485Description Specifi cation TypicalStabil

Page 17

24Test port input (dynamic accuracy)1Table 24. Option 230/235/240/245/260/265/280/285/430/435/440/ 445/460/465/480/485Accuracy of the test port input

Page 18 - Test Port Input

25Test port input (dynamic accuracy)1 (continued)Table 25. Option 2D5/2K5/4D5/4K5Accuracy of the test port input power reading is relative to –10 dBm

Page 19 - (continued)

26Test port input (group delay)1Table 26. Option 230/235/240/245/260/265/280/285/430/435/440/ 445/460/465/480/485Description Specifi cation Supplementa

Page 20 - 445/460/465/480/485

27Test port input (group delay)1 (continued)Table 27. Option 2D5/2K5/4D5/4K5Description Specifi cation Supplemental informationAperture (selectable) (f

Page 21 - Test port input (trace noise)

28General InformationTable 28. System bandwidthDescription General characteristicsIF bandwidth settingsRange 10 Hz to 500 kHzNominal settings are:10,

Page 22 - (continued)

29Table 30. Rear panel informationDescription Typical General characteristicsExternal trigger input connectorType BNC, femaleInput level Low threshold

Page 23 - Test port input (stability)

3OptionsThis document provides technical specifications for the E5071C ENA network analyzer and the E5091A multiport test set.E5071C-230 2-port test

Page 24

30Table 31. Rear panel information (continued)Description Typical General characteristicsBias tee input connectorType BNC, female (for each port)Maxim

Page 25 - Accuracy (dB)

31Description Typical General characteristicsLine power2Frequency 47 Hz to 63 HzVoltage 90 to 132 VAC, or 198 to 264 VAC (automatically switched)VA ma

Page 26 - Test port input (group delay)

32Table 34. EMC, safety and environmentDescription General characteristicsEMCEuropean Council Directive 2004/108/ECIEC 61326-1:2005EN 61326-1:2006CISP

Page 27

33Table 35. Analyzer environmental specifications and dimensionsDescription General characteristicsOperating environmentTemperature +5 °C to +40 °C E

Page 28 - General Information

34Figure 3. Dimensions (front view, E5071C with Option 230/235/240/245/260/265/280/285, in millimeters)Figure 4. Dimensions (front view, E5071C with O

Page 29

3542658 20 51 122 3727222261922Figure 5. Dimensions (front view, E5071C with Option 2D5/2K5, in millimeters) Figure 6. Dimensions (front view, E5071

Page 30

36Figure 7. Dimensions (rear view with Option 1E5, in millimeters)Figure 8. Dimensions (side view, E5071C Option 230/235/240/245/260/265/280/285/430/4

Page 31 - Table 33. LXI compliance

37Measurement Throughput SummaryCycle time for measurement completion1, 2 (ms) Table 36. Option 230/235/240/245/260/265/280/285/430/435/440/445/460/46

Page 32

38Number of points51 201 401 1601Start 100 kHz, stop 8.5 GHz, 500 kHz IF bandwidthUncorrected 15 18 19 242-port cal 28 35 38 484-port cal 55 69 74 104

Page 33

39Cycle time for measurement completion1, 2 (ms) Table 38. Option 230/235/240/245/260/265/280/285/430/435/440/445/460/465/480/485Sweep mode: Swept, an

Page 34 - 58 20 51 41 41 41 3727

4DefinitionsSpecification (spec.): Warranted performance. All specifications apply at 23 ºC (±5 ºC), unless otherwise stated, and 90 minutes after the

Page 35 - 58 20 51 122 3727

40Number of points51 201 401 1601Start 100 kHz, stop 8.5 GHz, 500 kHz IF bandwidthUncorrected 15 18 20 272-port cal 28 35 38 524-port cal 55 69 74 111

Page 36 - , in millimeters)

41Cycle time for measurement completion1, 2 (ms) Table 40. Option 230/235/240/245/260/265/280/285/430/435/440/445/460/465/480/485Sweep mode: Stepped,

Page 37

42Number of points51 201 401 1601Start 100 kHz, stop 8.5 GHz, 500 kHz IF bandwidthUncorrected 7.5 13 19 482-port cal 15 26 37 944-port cal 29 50 73 18

Page 38

43Cycle time for measurement completion1, 2 (ms) Table 42. Option 2D5/2K5/4D5/4K5Sweep mode: Swept, analyzer display turned off with: DISP:ENAB OFF, n

Page 39

44Number of points51 201 401 1601Start 11 GHz, stop 12 GHz, 500 kHz IF bandwidthUncorrected 3.0 3.2 4.9 172-port cal 5.6 6.1 9.9 374-port cal 11 14 23

Page 40

45Cycle time for measurement completion1, 2 (ms) Table 44. Option 2D5/2K5/4D5/4K5Sweep mode: Swept, analyzer display turned off with: DISP:ENAB OFF,nu

Page 41

46Number of points51 201 401 1601Start 11 GHz, stop 12 GHz, 500 kHz IF bandwidthUncorrected 3.0 3.4 5.9 202-port cal 5.6 6.6 12 434-port cal 11 14 26

Page 42

47Cycle time for measurement completion1, 2 (ms) Table 46. Option 2D5/2K5/4D5/4K5Sweep mode: Stepped, analyzer display turned off with: DISP:ENAB OFF,

Page 43 - 51 201 401 1601

48Number of points51 201 401 1601Start 11 GHz, stop 12 GHz, 500 kHz IF bandwidthUncorrected 2.8 6.4 11 312-port cal 5.1 13 21 614-port cal 9.6 24 41 1

Page 44

49Cycle time (ms)1, 2 vs. number of points Table 48. Option 230/235/240/245/260/265/280/285/430/435/440/445/460/465/480/485Start 1 GHz, stop 1.2 GHz,

Page 45

5Corrected System PerformanceThe specifications in this section apply to measurements made with the Agilent E5071C network analyzer under the followin

Page 46

50Cycle time (ms)1, 2 vs. IF bandwidthTable 50. All optionsSweep mode: Swept, analyzer display turned off with: DISP:ENAB OFF, number of traces = 1, s

Page 47

51Data transfer time1, 2 (ms)Table 51. All optionsNumber of points51 201 401 1601SCPI over GPIB364-bit fl oating point 4 12 25 8832-bit fl oating point

Page 48

52E5092A Configurable multiport test setThe section provides test input/output performance without calibration by the E5071C.Table 52. Test set input/

Page 49 - vs. number of points

53Description Specifi cation TypicalLoad match (common port)SPDT switch150 MHz to 2 GHz2 GHz to 4 GHz4 GHz to 8 GHz8 GHz to 10 GHz10 GHz to 20 GHz16 dB

Page 50 - vs. IF bandwidth

54Table 55. Control lineDescription Specifi cation TypicalNumber of groups 4Group A: 8 bitsGroup B,C,D: 4 bitsInput voltage range10 V to +5 V (positive

Page 51 - Data transfer time

55Table 59. Front panel informationDescription General characteristicsRF connectors SMA (Female)Test ports 38 portsControl line 15-pin D-sub, female25

Page 52

56Figure 11. Dimensions (pitch between switches, with Option E5092A-020, in millimeters, nominal)Figure 12. Dimensions (rear view, with Option E5092A-

Page 53

57Figure 14. Switch confi guration (E5092A-020)Figure 15. DC control line (E5092A-020)Control Line 1 (Group A)Control Line 2 (Group A)Control Line 3 (G

Page 54 - Table 56. DC source

58D-SUB 25pin assignmentLine 4Line 3Line 2Line 1Line 4Line 3Line 2Line 1Positive inputPositive inputNegative inputGNDDC sourceGNDDC source23 22 21 20

Page 55

59Option 230/235/240/245/260/265/280/285/430/435/440/445/460/465/480/485Table 62. Corrected system performance with type-N 75 Ω device connectors, 850

Page 56

6System dynamic range (continued)Table 2. Option 2D5/2K5/4D5/4K5 Description Specifi cation SPDSystem dynamic range1, 2300 kHz to 1 MHzIF bandwidth = 3

Page 57 - Positive Input

www.agilent.comwww.agilent.com/find/enaFor more information on Agilent Technolo-gies’ products, applications or services, please contact your local Ag

Page 58 - D-SUB 15 pin

7Corrected system performance with calibration kitOption 230/235/240/245/260/265/280/285/430/435/440/445/460/465/480/485Table 3. Corrected system perf

Page 59 - 85036E calibration kit

8Table 4. Corrected system performance with type-N device connectors, 85092C electronic calibration (ECal) module Network analyzer: E5071CCalibrati

Page 60 - Agilent Channel Partners

9Table 5. Corrected system performance with 3.5 mm device connector type, 85033E calibration kit Network analyzer: E5071CCalibration kit: 850