meter expands its use to include
many fluids with entrained solids
and gas bubbles. To extend the
benefits of the transit-time
method to more difficult applica-
tions, the PT868 uses a patented
acoustic signal-coding tech-
nique that greatly increases its
signal-to-noise ratio. This allows
the PT868 to make accurate,
drift-free flow measurements in
many two-phase flows contain-
ing gas bubbles, liquid droplets,
or entrained solids where con-
ventional transit-time meters fail.
M
ODEL
PT868R W
ITH
N
EW
T
RANS
F
LECTION
M
ODE
.
The
new PT868R is a dual-mode
flowmeter featuring both transit-
time and TransFlection mode
flow metering. Panametrics’ new
TransFlection ultrasonic flow
metering technology is available
exclusively from Panametrics. This
patented technique was devel-
oped for flow measurements in
multiphase fluids such as raw
sewage, sludge, slurries, tar sands,
oil-water-gas mixtures, acousti-
cally attenuating liquids, and
other demanding applications.
D
UAL
-C
HANNEL
M
ODEL
2PT868.
The TransPort 2PT868
flowmeter is also available as a
two-channel model for flow
applications requiring two simul-
taneous flow measurements with
one meter. The two measure-
ment points can be on different
pipes, or at two locations on the
same pipe. Either clamp-on or
wetted transducers can be
used at either location. The dual-
channel TransPort flowmeter
can also be set-up for two-path
flow measurement at a single
location for enhanced accuracy.
No matter how its used, this
model continuously measures
the selected flows on both
channels, as well as the sum, the
difference, and the average of
those two channels.
T
RANS
P
ORT
F
LOWMETER
O
PTIONS
, A
CCESSORIES
A
ND
S
PECIFICATIONS
.
The
TransPort PT868 Portable Liquid
Flowmeter is a complete port-
able ultrasonic flow metering
system with options and acces-
sories to meet all your flow
metering needs. Its the only
ultrasonic flowmeter that is avail-
able with two built-in measure-
ment technologies, the standard
transit-time mode and the
optional TransFlection
®
mode, to
cover the spectrum from ultra-
clean water to difficult multi-
phase flow applications. Other
options and accessories include:
single-channel and two-channel
models; a variety of wetted and
clamp-on transducers, clamping
fixtures and flowcells; resistance
temperature devices (RTDs) and
other accessories for energy flow
measurement; an ultrasonic
pipe-wall thickness transducer; a
thermal printer with accessories;
custom PC-interface software;
and a variety of power supplies
and accessories.
S
TANDARD
M
ODEL
PT868
W
ITH
T
RANSIT
-T
IME
M
ODE
.
The standard PT868 comes con-
figured for single-channel, transit-
time mode flow metering. Transit-
time is a very versatile method
that is suitable for most clean
liquids, and the TransPort flow-
The TransPort flowmeter
is the smallest, lightest,
full-featured transit-time
flowmeter available.
TRANSPORT
®
PT868 FLOWMETER
OPTIONS AND SPECIFICATIONS
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - OPTIONS AND SPECIFICATIONS

meter expands its use to includemany fluids with entrained solidsand gas bubbles. To extend thebenefits of the transit-timemethod to more difficult ap

Page 2 - Small-pipe clamping fixture

The PT868, The Ultimate Portable LiqFLOWTRANSDUCERS,CLAMPINGFIXTURES, ANDFLOWCELLS. With over 20years experience in ultrasonicflow measurement, Paname

Page 3 - The TransPort flowmeter

Just plug the thickness transducer cable into the flowtransducer inputs and you areready to make wall thicknessmeasurements. Enter a pipematerial into

Page 4 - Accurate Measurements

and stored in PC memory. You can also export data tospreadsheets, word processors,database management, orother software packages forgraphing, reportin

Page 5 - Flowmeter—From Panametrics

Energy Accuracy:The accuracy of the energy measurement is a combi-nation of the accuracy of the associated flow and temperature measurements.Transit-T

Page 6 - ISO 9002