Atec Dewetron-DEWE2_DatatsheetЙ User Manual

Browse online or download User Manual for Equipment Atec Dewetron-DEWE2_DatatsheetЙ. Atec Dewetron-DEWE2_DatatsheetЙ User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Series Modules

1Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2DEWE2Modular Data Acquisition Syste

Page 2 - System Architecture

www.dewetron.com10DEWE2 All-In-One InstrumentsDEWE2-A4 DEWE2-A7 DEWE2-A13Slots for TRION™ acquisition modules 4 7 13Dynamic channel expansion Ethern

Page 3 - One software for all

SYNCPCIe PCIeDEWE-818DEWE2-F18DEWE2-F18DEWE2-F4sPCIe connection up to 7 metersPCIe connection up to 7 metersTRION-SYNC-busDEWE2-A4 with option DW2-LI

Page 4

www.dewetron.com12DEWE2-M4 DEWE2-M4s DEWE2-M7s DEWE2-M13s DEWE2-M13Slots for TRION™ acquisition modules 4 4 7 13 13Dynamic channel expansion Ethernet

Page 5 - User exchangeable modules

13Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2DEWE2-M4 DEWE2-M4s DEWE2-M7s DEWE2

Page 6 - High channel density

www.dewetron.com14DEWE2-A4 / M4DEWE2-A4 / M4 4 slots for TRION™ series modules Isolated wide range DC power supply Optional internal buffer battery

Page 7 - Board Voltage [V]

15Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2DEWE2 Options, Upgrades, Accessori

Page 8 - Factory installation only

www.dewetron.com16DEWE2-A7 / A13 7 / 13 slots for TRION™ series modules Powerful Intel® Core™ i7 processor Brilliant 17'' full-HD display

Page 9 - IRIG SOURCE

17Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2SYSTEM OPTIONSDW2-A13-PS-BATUpgrad

Page 10 - A-series

PCIe connection up to 7 meters (250 MB/s)TRION-SYNC-buswww.dewetron.com18DEWE2-M4s / M7s / M13sDEWE2-M4s / M7s / M13s 4/7/13 slots for TRION™ series

Page 11 - F-series

MOB-DISP-12 External display19Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2DEWE2

Page 12 - M-series

High speed data interfacewww.dewetron.com2Data Acquisition Module System ArchitectureUser exchangeable TRION™ modules Binary / counter / timer

Page 13 - DEWE2 Mainframes

PCIe connection up to 7 metersTRION-SYNC-busDEWE2-F18 with optionDW2-LINK-PCIE-2-SDEWE2-M13 with TRION-TIMING moduleand LINK-HOST-PCIE cardwww.dewetro

Page 14 - DEWE2-A4 / M4

21Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2SYSTEM OPTIONSDW2-PS-AC-REDRedunda

Page 15

PCIe connection up to 7 meters (250 MB/s)TRION-SYNC-buswww.dewetron.com22DEWE2-F4s / F7s / F13sDEWE2-F4s DEWE2-F7s DEWE2-F13sSlots for TRION™ modules

Page 16 - DEWE2-A7 / A13

BAT-CHARGER-1 BAT-CHARGER-4 DW2-UPS-150-DC,130 W UPS with 2 slots for batteries23Software Components Signal Conditioning Front-ends In

Page 17 - Carrying bag

SYNCSYNCSYNCPCIePCIePCIe PCIewww.dewetron.com24DEWE2-F18 18 slots for TRION™ series modules PCI Express data link 120 MB/s data transfer rate 19&

Page 18 - DEWE2-M4s / M7s / M13s

25Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2 Series Modules Series Modules Ove

Page 19

www.dewetron.com26 Series Modules

Page 20 - DEWE2-M13

27Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2 Series Modules

Page 21

TRION-2402-dACC-8-SMBTRION-2402-dACC-6-BNCwww.dewetron.com28 Differential multi-function input module Sampling: 24 bit; 204.8 kS/s per channel

Page 22 - DEWE2-F4s / F7s / F13s

29Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2 Series ModulesCables for TRION-24

Page 23

3Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2Housing and Storage Controlling

Page 24 - DEWE2-F18

www.dewetron.com30 Differential universal input module Sampling: 24 bit; 204.8 kS/s per channel Input types: Voltage up to ±10 V Strain ga

Page 25 - Series Modules Overview

31Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2Cables for TRION-2402-dSTG modules

Page 26

www.dewetron.com32 Isolated wide range voltage module Sampling: 24 bit; 204.8 kS/s per channel Input types: Voltage ±300 mV to ±100

Page 27

33Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2 Series ModulesShuntsDAQ-SHUNT120

Page 28 - TRION-2402-dACC

www.dewetron.com34 Counter, DIO and synchronization module Counter channels: 2 SuperCounters™ Digital I/O: 8 DIO and 8 DI Synchronization: I

Page 29

35Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2 Timing and synchronization mo

Page 30 - TRION-2402-dSTG

www.dewetron.com36 Series Modules Isolated SuperCounter™ module Sampling 80 MHz time base 204.8 kS/s per channel Input types Event,

Page 31 - Mating connector

37Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2 Series Modules Isolated digit

Page 32 - TRION-2402-V

www.dewetron.com38 Isolated high speed CAN interface Input types High speed, (low speed and single wire with optional converter) Listen only

Page 33

39Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2 ARINC 429 module with up to

Page 34 - TRION-BASE

www.dewetron.com4All-in-one instruments MainframesFront-ends Most compact, includes powerful i7 computer, brilliant display and keyboard, touchpad.Mos

Page 35 - TRION-TIMING

www.dewetron.com40 Series Modules Analog output module 2 channel TRION™ analog output module, based on NI PXI-6251 voltage range max. ±10 V 16

Page 36 - Cables for TRION-CNT modules

SYNC-CLOCK™insideAnalog Digital Bus system GPS Video Sensor systemDEWETRON INSTRUMENTRECORDINGSYNC5Software Components Signal Conditioning

Page 37 - Options for TRION-DIO modules

www.dewetron.com6DEWE2 Advantages Perfectly synchronized to analog and all other inputs Accepts any signal wave form, trigger level from 0 to 50 V

Page 38 - Cables for TRION-CAN modules

Board Voltage [V]7Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2DEWE2 AdvantagesHi

Page 39 - TRION-A429

www.dewetron.com8SYNC it all!DEWE2 SynchronizationSynchronization of multiple DEWE2 systems via Sync-cableSync via TRION™ modulesTo use TRION-BASE or

Page 40 - TRION-1628-AO-2

9Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2IRIG SOURCEVIDEO-SYNCHardware synch

Comments to this Manuals