Technical Data Sheet
The Anritsu Family of Pulse, Wideband and
CW Power Meters, and Power Sensors
ML2400A Power Meters and MA2400A/D Power Sensors
Ideal solutions for Average, Peak, and Crest Power measurements
Anritsu Power Meters and Power Sensors:
Accurate, Fast, and
Affor
dable.
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Technical Data Sheet

Technical Data SheetThe Anritsu Family of Pulse, Wideband andCW Power Meters, and Power SensorsML2400A Power Meters and MA2400A/D Power SensorsIdeal s

Page 2 - Introduction

10Power Meter ModelsML2495A Power Meter, Single InputML2496A Power Meter, Dual InputML2487A Power Meter, Single InputML2488A Power Meter, Dual InputML

Page 4

Technical Data Sheet No. 11410-00423, Rev. A Printed in United States 2007-05®Anritsu All trademarks are registered trademarks oftheir respective comp

Page 5

2IntroductionAnritsu offers the world's most comprehensive range of power meters. The ML2490A series has the performance requiredfor narrow fast

Page 6

3Power Meter SpecificationsML2430A Series ML2480A Series ML2490A Series CommentsML2437A ML2438A ML2487A ML2488A ML2495A ML2496ASignal Inputs 1 2 1 2 1

Page 7

4ML2430A Series ML2480A Series ML2490A Series CommentsML2437A ML2438A ML2487A ML2488A ML2495A ML2496AOperation22 (CW or Pulse/Modulated measurement mo

Page 8 - Power Sensor Specifications

5ML2430A Series ML2480A Series ML2490A Series CommentsML2437A ML2438A ML2487A ML2488A ML2495A ML2496AAveragingAuto (Moving), Manual (Moving, Repeat) T

Page 9 - Measurement Accuracy

6ML2430A Series ML2480A Series ML2490A Series CommentsML2437A ML2438A ML2487A ML2488A ML2495A ML2496ATriggeringN/A ±2 ns for pre and post trigger (Tri

Page 10 - Ordering Information

7ML2430A Series ML2480A Series ML2490A Series CommentsML2437A ML2438A ML2487A ML2488A ML2495A ML2496AReference Calibrator1mW Power±1.2% per year, ±0.9

Page 11

8Power Sensor SpecificationsFrequency Range CW Dynamic Range(dBm) SWR Rise Time1(ms) Sensor Linearity6RFConnector2Standard Diode Sensors MA2472D 10 M

Page 12 - ANRITSU Corporation

9Measurement AccuracyPower measurement accuracy can be split into several parts.The table below shows how the measurement uncertainty iscomposed for s