Agilent N8300A With N630XA The Agilent N8300A wireless networking test sbox radio frequency (RF) parametric test
10 Application Software N6302A-1FP - 802.11a,b,g,n WLAN measurement application, fixed perpetual licen
11 Analyzer performance Frequency specifications Frequency range 2.381 to 2.519 GHz (Options
12 Amplitude specifications for the RF Output port Output amplitude range1 2.402 to 2.484 GHz: +20 to -100 dBm (CW); 4.8 to 5.875 GHz: +13 to
13 Related Literature Agilent N8300A Wireless Networking Test Set, brochure, literature number 5989-7063EN N6301A 802.16 OFDMA Measurement App
www.agilent.com www.agilent.com/find/n8300a For more information on Agilent Technologies’ products, applications or services, please contact your
2 Definitions and Conditions N8300A Hardware Specifications Specification Specifications describe the performance parameters
3 VSG performance Performance Sample rate To 125 MSa/s Bandwidth 100 MHz Effective DAC resolution 16 bits Frequency specifications Frequenc
4 VSA performance (RFIO 1 to 4 specifications)1 Frequency specifications Frequency range Refer to Application Software section Amplitude spe
5 Power requirements Power consumption < 270 W maximum Data storage External Supports USB 2.0-compatible
6 Inputs and Outputs Front panel RF In/Out Connector Type-N female, 50 Ω nominal RF output Connector Type-N female, 50 Ω nominal USB por
7 Rear panel (continued) SOURCE TRIG IN Accepts TTL and CMOS level signals for triggering point-to-point in sweep mode. Damage levels are ≤ –0.3
8 Application Software N6301A-1FP 802.16 OFDMA measurement application (Mobile WiMAX) N6301A-2FP 802.16 OFDM measurement application (Fixed WiMAX
9 N6301A key specifications (continued) Source performance Frequency specifications Frequency range 1.765 to 1.815 GHz; 2.15 to 2.71 GHz; 3.3
Comments to this Manuals