Atec Agilent-4339B_4349B User Manual

Browse online or download User Manual for Equipment Atec Agilent-4339B_4349B. Atec Agilent-4339B_4349B User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Within Budget
Without Compromise
Introducing the Agilent Technologies
4339B and 4349B High Resistance
Meters Used for Making Ultra-
High Resistance Measurements
For precision bench-top applications,
the 1-channel 4339B is the premier
solution for accurate high resistance
and low current tests. For high resist-
ance testing in manufacturing envi-
ronments, the 4349B offers simulta-
neous 4-channel high resistance
measurements for increased test
throughput.
Satisfy Your Needs for ...
High quality results
High confidence testing with
contact check function
Remove parasitics with error
correction
Consistent data with 0.6% basic
accuracy
Compensation for handler contact
chattering with trigger delay
Versatile measurements
Select from four test parameters
Use a variety of test fixtures
and accessories
Perform a charge-measure-
discharge sequence with the test
sequence program function
Save and recall up to ten
measurement setups
High test throughput: 4349B
9.5 ms measurements
4-channels for multiple DUTs
4-channel simultaneous testing
Fast contact checking: 2 ms/
measurement
GPIB and handler interfaces
Ideal for high volume capacitor
testing
Agilent
4339B/4349B High Resistance Meters
Technical Overview
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Agilent

Within BudgetWithout CompromiseIntroducing the Agilent Technologies4339B and 4349B High ResistanceMeters Used for Making Ultra-High Resistance Measure

Page 2

2Open:Compensates leakage current and capacitance in test fixtures and cables.Contact check: Verifies reliability of capacitor test connections.Save/R

Page 3

3High quality measurements with flexible hardware• Resolve data to 5 digits (3, 4, or 5 digits selectable)• Make precise measurements with 0.6% basic

Page 4 - Measurement Accuracy

4Specifications Measurement AccuracyAgilent 4339B test conditions*: 1. Warm up time: ≥ 30 minutes2. Ambient temperature: 23 °C ± 5 °C3. Test cable len

Page 5

5Agilent 4349B test conditions1:1. Warm up time: ≥ 30 minutes2. Ambient temperature: 23 °C ± 5 °C3. Test cable length: ≤ 1.5 meters4. Open error corre

Page 6 - Other Specifications

6Other SpecificationsMeasurement parameters/rangesParameter RangeAgilent 4339BR (dc resistance) 103 Ω to 1.6 x 1016 ΩI (dc current)

Page 7 - Test Fixtures/Accessories

7Test Fixtures/AccessoriesAgilent 16339A component test fixtureFor manual high voltage testing ofdescrete components. For 4339B only.Agilent 16117B lo

Page 8 - Agilent Email Updates

Ordering Information❍ = Choose ONE and ONLY oneq = Choose any combinationAgilent 4339B High Resistance Meter1Furnished accessories: shunt connectorDoc

Comments to this Manuals