Agilent 53200A Series
RF/Universal Frequency
Counter/Timers
Data Sheet
53210A 350 MHz RF Frequency Counter, 10 digits/sec
53220A 350 MHz Universal Frequency Counter/Timer, 12 digits/sec, 100 ps
53230A 350 MHz Universal Frequency Counter/Timer, 12 digits/sec, 20 ps
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Counter/Timers

Agilent 53200A SeriesRF/Universal Frequency Counter/TimersData Sheet53210A 350 MHz RF Frequency Counter, 10 digits/sec53220A 350 MHz Universal Frequen

Page 2 - Introduction

1053210A 53220A 53230AMath operationsSmoothing (averaging) 1Selectable 10 (slow), 100 (medium), 1,000 (fast) reading moving averageSelectable filter r

Page 3 - Input Channel Characteristics

1153210A 53220A 53230AMeasurement/IO timeout (nom)no timeout or 10 ms to 2000 s, in 1 ms stepsAuto-level speed Slow mode (50 Hz): 350 ms (typ) Fast m

Page 4

1253210A 53220A 53230AMaximum measurement speed to internal non-volatile memory6: (readings/s)Timestamp N/A N/A 1,000,000Frequency, period, totalize3

Page 5 - Measurement Characteristics

1353210A 53220A 53230AWarm-up time 45-minutesDisplay 4.3" Color TFT WQVGA (480 x 272), LED backlightUser interface and help languagesEnglish, Ger

Page 6

1453210A 53220A 53230ABattery (Option 300)Technology Internal lithium ion battery with integrated smart battery monitor & chargerUse for maintaini

Page 7

15TimebaseStandardTCXOOption 010Ultra-High Stability OCXOAging 1 (spec) 24-hour, TCAL ±1 °C ± 0.3 ppb (typ) 30-day, TCAL ±5 °C ± 0.2 ppm (typ) ± 1

Page 8

16Basic accuracy 1 = ± [(k * Random Uncertainty) + Systematic Uncertainty + Timebase Uncertainty] Measurement Function 1-σ Random Uncertainty Systemat

Page 9

17Accuracy Specifications continuedMeasurement Function 1-σ Random Uncertainty Systematic UncertaintyTimebase Uncertainty26 GHz (Option 106): Optional

Page 10

181. Apply the appropriate errors detailed for each measuring function. 2. Use Timebase Uncertainty in Basic Accuracy calculations only for Measuremen

Page 11 - Speed Characteristics

19Resolution enhancement factor (RE) The resolution enhancement (RE) calculates the added frequency resolution beyond the basic reciprocal measurement

Page 12 - (meas) continued

2IntroductionFrequency counters are depended on in R&D and in manufacturing for the fastest, most accurate frequency and time interval measurement

Page 13 - General Characteristics (nom)

20±(0.2%-of setting + 0.1%-of range) V/s (at threshold point) Definition of Measurement Error Sources and Terms used in Calculations continuedPhase No

Page 14

21Ordering InformationModel numbers53210A 350 MHz, 10-digits/s RF Frequency Counter 53220A 350 MHz, 12 digits/s, 100 ps Universal Frequency Counter

Page 15 - Timebase

22Parameter assumptions:• 53220A• 95% confidence• 100 MHz signal, 1 sec gate• AUTO frequency mode• Level: 5 V input signal amplitude• TCXO standard ti

Page 16 - Accuracy Specifications

23Specifi cation (spec) The warranted performance of a calibrated instrument that has been stored for a minimum of 2 hours within the operating temper

Page 17

www.lxistandard.orgLAN eXtensions for Instruments puts the power of Ethernet and the Webinside your test systems. Agilent is a founding member of the

Page 18

353210A 53220A 53230AInput characteristics (nom)ChannelsStandard (DC - 350 MHz) Ch 1 Ch 1 & Ch 2Optional (6 or 15 GHz) Ch 2 Ch 3Standard inputs

Page 19

453210A 53220A 53230AOptional microwave inputs (nom)Frequency rangeOption 106 100 MHz - 6 GHzOption 115 300 MHz - 15 GHzInputConnector Front panel pre

Page 20

553210A 53220A 53230AMeasurement range (nom)Frequency, period (average) measurementsCommonChannels Ch 1 or optional Ch 2 Ch 1, Ch 2 or optional Ch 3Di

Page 21 - Ordering Information

653210A 53220A 53230ATime interval A to B, B to ARange9N/A -1 ns to 100,000 s (nom)-0.5 ns to 100,000 s (min)Time interval A or BRange N/A 2 ns to 100

Page 22 - Appendix A - Worked Example

753210A 53220A 53230A6 GHz (Option 106) 15 GHz (Option 115)Pulse/burst frequency and pulse envelope detector (Option 150)12Pulse/burst measurements N/

Page 23 - Definitions

8Gate, Trigger and Timebase Characteristics53210A 53220A 53230AGate characteristics (nom)GateSource Time, external Time, external or advancedGate tim

Page 24 - Agilent Channel Partners

953210A 53220A 53230ATrigger characteristics (nom)GeneralTrigger source Internal, external, bus, manualTrigger count 1 to 1,000,000 Trigger delay 0 s