TECHNOLOGY · TEST PROCESSES · ENGINEERING SERVICES
DATA SHEET
SPECIFICATIONS MB500VI MB1000VI
FrequencyRange DC20,000Hz,‐3dB,useableto
60kHzatreducedoutputpower
DC20,000Hz,‐3dB,useableto
60kHzatreducedoutputpower
InputCoupling ACorDC ACorDC
FeedbackMode VoltageorCurrent,switchable
withexternaltoggleswitch
VoltageorCurrent,switchable
withexternaltoggleswitch
InputImpedance >10k >10k
InputPowerRequirements 100‐‐ 240VAC;4862Hz 100 240VAC;48/62Hz
InputPowerRequired 1,000VA (max) 2,000VA(max)
Max.OutputVolts 25VRMS 45VRMS
Max.OutputAmps 25ARMS(35APk) 25ARMS(35APk)
OverCurrent&Voltage
Protection
Useradjustabletripsand clipping Useradjustabletripsandclipping
OverTemperatureProtection Yes Yes
Ethernet Amplifier
and Remote Shutdown
SeeOptions onfollowingpages SeeOptionsonfollowingpages
ShakerCooling&Overtravel SeeOptions onfollowingpages SeeOptionsonfollowingpages
CurrentMeasurem ent BNC,250mV/A;frontpanelLCD BNC,250mV/A;frontpanelLCD
TotalHarmonicDistortion 0.5%@100Hz/10VRMS 0.5%@100Hz/10VRMS
Dimensions(rackmount) 3½”H(2HE); 19”W(482mm);
14¼”D(362mm)
7”H(4HE); 19”W(482mm);
14¼”D(362mm)
SignalInforFullPowerOut
±3Vpk(Factory)
(Int.switch:±1,3,5,10Vpk)
±3Vpk(Factory)
(Int.switch:±1,3,5,10Vpk)
SignaltoNoiseRatio >100dB >100dB
WeightorMass 33lbs(15kg) 73lbs(33kg)
CEMark Yes Yes
ApplicationNote(Manual) Yes Yes
Specificationssubjecttochangewithoutnotice
MB500VI and MB1000VI
Power Ampliers
Specications and Options
Page view 0
1 2 3

Summary of Contents

Page 1 - MB500VI and MB1000VI

TECHNOLOGY · TEST PROCESSES · ENGINEERING SERVICESDATA SHEETSPECIFICATIONS MB500VI MB1000VIFrequencyRange DC‐20,000Hz,‐3dB,useableto60kHz

Page 2 - DATA SHEET

Opons for the MB500VI and MB1000VI AmpliersOpon 1: Ethernet Amplier OperaonEach amplier with this opon has an embedded microcontroller with an

Page 3 - www.mbdynamics.com

Opon 2: Exciter Cooling ON/OFF with Overtravel ShutdownEach amplier with this opon monitors the temperature of the exciter coil and turns ON or OFF

Comments to this Manuals