Atec Vishay-2311 User Manual

Browse online or download User Manual for Equipment Atec Vishay-2311. Atec Vishay-2311 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 7
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Sales Contacts
Brands Vishay Measurements Group Interactive Guide Instruments 2300 System
Model 2311
Model 2311
Signal Conditioning Amplifier
Description
While the Model 2311 provides wider frequency response and more
versatile excitation, both 2310 and 2311 Signal Conditioner/Amplifier
Modules accept inputs from strain gages, load/pressure/dc displacement
transducers, potentiometers, thermocouples, RTD's and nickel temperature
sensors, without any internal modification.
Controls on the 2311 are arranged in sections, permitting easy setup.
Clearly marked push-button and single-purpose switches minimize the
possibility of operator error during use. With the exception of the playback
switch, all operational and monitor controls are on the front panel. Switches
for selecting remote sense and specific shunt calibration configurations are
located on the printed circuit board inside the unit.
Front Panel
Galvanometer: Electronic adjustment for zero positioning
and span of the galvanometer, remote from recorder.
Calibration: Momentary two-position switches, +A and +B,
control shunt calibration levels; 4 point.
LED Display: Set up indicator for amplifier balance, bridge
balance and for monitoring the output polarity.
Filter Section: Push-button controls for activating appropriate
low-pass active filter, or selecting wide-band operation (WB).
Electronic Bridge Balance Section: Three-position
switch--OFF, ON, RESET--for electronic bridge balance; auto
ranging up to +25 000 microstrain with nonvolatile zero
storage; yellow light indicates high-range operation or
Model 2311 (Signal Conditioning Amplifier): Strain Gage Instruments
http://www.vishay.com/brands/measurements_group/guide/inst/2300/2311.htm (1 of 7) [12/9/2002 9:47:40 AM]
Page view 0
1 2 3 4 5 6 7

Summary of Contents

Page 1 - Signal Conditioning Amplifier

Sales ContactsBrands Vishay Measurements Group Interactive Guide Instruments 2300 System Model 2311Model 2311Signal Conditioning Amplifie

Page 2 - Specifications

overrange condition. Vernier TRIM control is used to refinebridge balance when desired.AC IN: Capacitive coupling in the amplifier; eliminates staticc

Page 3

All specifications nominal or typical at +23 deg C unless noted.InputStrain Gages:Quarter(120 ohms or1000 ohms and 350 ohms), half or full bridge (50

Page 4

microstrain (0.0012 mV/V).+25 000 microstrain (5% bridge unbalance or 12.5 mV/V), resolution 12.5microstrain (0.006 mV/V).Balance Time:2 seconds, typi

Page 5

Frequency Response, Reduced Output (2 Vrms max): Bandwidth (-3 dB) at Gain of: 1-11, 200 kHz; 10-110, 170 kHz;100-1100, 135 kHz; 1000-11 000, 125

Page 6

Tape Output:+1.414V (1 Vrms) at 5 mA, min.Galvanometer Output:+10V at 75 mA, min, current-limited at 100 mA, max (minimum loadresistance for 0.05% lin

Page 7 - Page 3 of 7

Page 3 of 7Model 2311 (Signal Conditioning Amplifier): Strain Gage Instrumentshttp://www.vishay.com/brands/measurements_group/guide/inst/2300/2311.htm

Comments to this Manuals

No comments