HMI41 Indicator and HMP42/HMP46 Probes
The Vaisala HUMICAP
®
Humidity
Indicator HMI41 fitted with the Vaisala
HUMICAP
®
Humidity and Temperature
Probes HMP42 or HMP46 can be used
for spot checking and field calibration
applications.
In addition to displaying the humidity
and temperature readings, the HMI41
indicator calculates dew point and wet
bulb temperature, absolute humidity
and mixing ratio.
The indicator has an easy-to-read two
line liquid crystal display. The display
units (metric or non-metric) are easily
selected.
These features, plus fast response
time, high measurement accuracy and
excellent stability, as well as the unique
properties of the probe chosen – either
the HMP42 or the HMP46 – make
the HMI41 indicator and HMP42/46
combination an ideal choice for the
most demanding applications.
Vaisala HUMICAP®
Humidity and Temperature
Probe HMP42
The HMP42 probe can be used for spot
checking humidity and temperature
in applications which require an
extremely thin probe. Typically the
probe is used for monitoring the drying
of structures during construction or
after water damage. It is ideal to be
used when measuring in any tight
places, in ducts or chambers or, for
example, under a linoleum floor.
The probe diameter is only 4 mm,
allowing access into very small, tight,
and hard-to-reach spaces.
Vaisala HUMICAP®
Humidity and Temperature
Probe HMP46
Typical applications for the HMP46
are plant maintenance, installation
and inspection of air conditioning
systems, production and storage areas
and production processes. The HMP46
operates in full humidity range of
0 ... 100 %RH. The temperature range
is from -40 to +100 °C (-40 ... +212 °F).
For short periods of time, the probe
can withstand temperatures up to
+180 °C (+356 °F).
The HMP46 probe is solid and
rugged. Its stainless steel probe is
made to withstand rough handling in
mechanically demanding applications.
The probe’s long shaft can also reach
otherwise unreachable places.
High Performance Sensor
The HMP42/46 probes incorporate
Vaisala HUMICAP
®
Sensor. This sensor
has high accuracy, excellent long-term
stability and negligible hysteresis.
In addition, the sensor is insensitive
to dust, particulate dirt and most
chemicals.
Features/Benefits
RH measurement range
0 ... 100 %RH
Temperature measurement
range -40 ... +100 °C
(-40 ... +212 °F), with the
HMP46 only for short periods
up to +180 °C (+356 °F)
Calculates dew point, wet bulb
temperature, absolute humidity
and mixing ratio
Versatile and easy-to-use
Incorporates Vaisala HUMICAP®
Sensor
Excellent stability
Data collection with serial line
NIST traceable (certificate
included)
Optional carrying case and
calibration cable
The Vaisala HUMICAP
®
Humidity
Indicator HMI41 equipped with the
Vaisala HUMICAP
®
Humidity and
Temperature Probe HMP46 – a rugged
stainless steel probe for mechanically
demanding and high temperature
applications.
The Vaisala HUMICAP
®
Humidity
Indicator HMI41 equipped with the
Vaisala HUMICAP
®
Humidity and
Temperature Probe HMP42 – an
extremely thin probe allowing access
into very small, tight, hard-to-reach
spaces.
Page view 0
1 2 3

Summary of Contents

Page 1 - Features/Benefits

www.vaisala.comHMI41 Indicator and HMP42/HMP46 ProbesThe Vaisala HUMICAP® Humidity Indicator HMI41 fitted with the Vaisala HUMICAP® Humidity and Tempe