Temperature Range:
1,3
-80
° to +225°C (60 Hz System)
-75° to +225°C (50 Hz System)
Typical Temperature Transition Rate (air)
1,2
-55° to +125°C: approximately 10 seconds or less
2
+125
° to -55°C: approximately 10 seconds or less
2
System air flow output
2.4 to 9 liters/second (5 to 18 scfm) CONTINUOUS
Temperature accuracy 1.0°C (when calibrated against NIST transfer standard)
Temperature set, display and resolution ± 0.1°C
Temperature Control:
DUT Sensor Ports Type T and Type K Thermocouple ports standard
DUT Control Control to within ± 0.1°C; SELF-TUNING available in DUT Control
Remote interface ports IEEE-488, RS232C Serial, and Start Test/End of Test/Stop
on First Fail (ST/ET/SFF)
1
Note: Ultimate low temperature and system performance may vary under operating conditions less than or greater than nominal.
2
Note: Transition performed under nominal operating conditions.
3
Note: Low temperature extremes can be achieved at reduced airflow rates.
Model TP04310A ThermoStream
®
System Specifications
4
Note: US Patent no. 4,734,872
TP04310A
TEMPERATURE PERFORMANCE AND AIRFLOW CAPACITY
USER FEATURES
Modes of Operation Two: Manual and Program Modes
Test set-up configurations 12 Manual Mode test programs and 12 Program Mode
test programs may be created
Test set-up storage 11 Manual Mode test programs, 11 Program Mode
test programs and 11 affiliated “Define Parameters”
test set-ups can be stored for later recall.
Ramp/soak/cycle configurations
In Program Mode, up to 12 sequences per test set-up;
table is displayed on-scr
een
DUT temperature control Patented
4
Dual Loop Temperature Control
Status indicators Real-time status displayed on-screen and via remote
interface
Purge flow tester interface Dry air purge protects tester electronics
protection from condensation
Purge flow capacity 0.25 to 1.5 liters per second (0.5 to 3 scfm) airflow
Calibration Automated, simplified and accurate for all airflows
and DUT types
Thermal head raising and lowering Pneumatic control on thermal head,
operated manually or via remote interface
Head positioner movement
Manual locking (4 locks), 360
°
head rotation; head
can be manually pivoted, turned, tilted and vertically
swung for ease of interface at tester site.
Manipulator (ar
m) movement
Motorized raising and lowering of arm;
330° positioning range around the base unit
Part No. SL10290 R/C
Mobile Temperature System for testing components, hybrids, parts, modules,
subassemblies and printed circuit boards at precise temperature
Page view 0
1 2

Summary of Contents

Page 1 - TP04310A

Temperature Range:1,3-80° to +225°C (60 Hz System)-75° to +225°C (50 Hz System)Typical Temperature Transition Rate (air)1,2-55° to +125°C: approximate

Page 2 - Specifications

Over-Temperature Protection +235°C (factory-set) (Also uses user-settable high and low air temperature limit)Mobility 4 swivel caster wheels with lock