Approved for public release by AR RF/Microwave Instrumentation 092412
160 School House Road Souderton, PA 18964-9990 • 215-723-8181 • www.arworld.us Page 1 of 2
Model CI00400A,
M1 through M7
RF Conducted Immunity System
100 Watts nominal
10 kHz–400 MHz
Complete testing solutions to the following standards:
MIL-STD-461D & E CS114
DO160D & E BCI Testing
EN/IEC 61000-4-6
IEC 60601-1-2
EN 50130-4
EN 61000-6-1/2
EN 55024
The Model CI00400A is a fully self-contained state of the art system
designed to test RF Conducted Immunity. The system contains a signal
generator, 3 channel power meter, 100W nominal AR amplifier 10kHz to
400MHz, directional coupler, and emcware® control software. Everything is contained in a single housing, which
eliminates setup issues. This system provides the versatility needed for every test laboratory and equipment manufacturer.
The RF amplifier and the signal generator can be used independently of the system. If special needs arise or standards
were to change a larger amplifier can be connected to the system. The use of spectrum analyzers and monitoring
equipment may also be controlled by the software.
Option 1 adds an additional power head for testing automotive standards such as Ford, GM, Chrysler, BMW, Renault,
and ISO11452-4. Option 2 adds data acquisition capability. Option 3 provides a laptop PC preloaded with the test
software. Option 4 is a lower cost solution providing all the functions and features of the full CI00400A base model
without the cost of the internal amplifier.
The export classification for this equipment is EAR99. These commodities, technology or software are controlled for export
in accordance with the U.S. Export Administration Regulations. Diversion contrary to U.S. law is prohibited.
Internal Test Specifications (See NOTE 1)
CI00400A CI00400A w/Option 1
All standards of CI00400A plus:
MIL-STD-461D (CS114)
MIL-STD-461E (CS114) ISO 11452-4
DO160D (Sec 20 BCI Test) GMW 3097
DO160E (Sec 20 BCI Test) Ford ES-XW7T-1A278-AC
IEC/EN 60601-1-2 DaimlerChrysler DC-11224
IEC/EN 50130-4 BMW GS95002
IEC/EN 61326 Renault 36-00-8081-G
IEC/EN 61000-6-1
IEC/EN 61000-6-2
IEC/EN 61000-4-6
CISPR 24/EN 55024
Signal Generator Specifications
Frequency range
resolution
9 kHz to 1.2 GHz
1Hz
Power range
resolution
-140 to +13 dBm
0.1dB
Modulation AM, FSK. FM, Phase, External
Pulse
Power Meter Specifications (See NOTE 2)
Channels 3
Power heads 2
Type diode
Frequency 10kHz to 8GHz
Range -60 to +20 dBm
NOTE 1: Specifications can be met using AR-specified external accessories (injection probes, monitor probes, cal fixtures, CDN’s,
attenuators, etc.) Contact AR for further information.
NOTE 2: The use of a spectrum analyzer may be necessary on some of the low level bulk current injection tests. This is especially true on
power and I/O lines with a great amount of ambient noise.