Guardian
USES:
Production and Compliance Testing of
Appliances, Instruments and Information
Technology Equipment in Accordance
with UL, CSA, IEC, TUV and Other
Standards such as EN60335, EN60950,
EN61010, CSA C22.2 No. 1010.1, UL3111
and UL1950
Transformer Electrical Safety Testing
Electric Motor Safety Testing
Power Supply Safety Testing
Verification of the Ground Connection on
Products with a Three Prong Power Cord
FEATURES:
Programmable output voltage to 5KVAC
and 6KV DC
Ground Bond Testing to 30AAC with
Adjustable Limit
Insulation Resistance Measurements
from 100k
to 50G
Programmable Ramp and Test Times
Storage of 99 Tests Setups with 99 Steps
per Setup
Continuous Leakage Current Monitoring
Trip Current Programmable to 40mAAC
and 20mA DC
Front Panel Lockout via Password
Standard IEEE and Remote Control
Interfaces
Optional RS232, Printer Interfaces
Built-in 8 Channel Scanner Option
Introduction
The Guardian 6000 is four instruments in one providing AC Hipot, DC Hipot,
Insulation Resistance and Ground Bond measurements from a single test connec-
tor in one versatile instrument. This provides a cost effective solution to electrical
safety compliance testing with maximum flexibility for present and future
requirements. Performing multiple electrical safety tests in one unit can reduce
test time, increase productivity and reduce the number of instruments requiring
calibration.
Description
The Guardian 6000 AC Hipot Tester performs AC dielectric testing (hipot)over
the voltage range from 50V to 5000VAC RMS. The maximum leakage current of
40mA RMS makes the Guardian 6000 ideal for testing devices with high leakage
currents such as power supplies which have large filter or “Y” capacitors for noise
reduction.
The Guardian 6000 DC Hipot Tester voltage range for DC dielectric testing is
50V to 6000VDC with a resolution of 1V. The maximum current leakage is
20mA which allows quick charging of capacitive devices. A quick discharge of
the device when the measurement is complete, also minimizes test times.
Leakage currents can be monitored down to 0.1µA.
The Guardian 6000 Insulation Resistance measurements are similar to a DC
hipot but rather than displaying leakage current, resistance is calculated and dis-
played. The insulation resistance can be measured over the range of 100k to
50Gwith test voltages from 50VDC to 1000VDC in 1V steps.
The Guardian 6000 Ground Bond provides up to 30AAC for ground bond test-
ing. The test current can be programmed from 1A to 30A in 0.1A steps. Hi cur-
rent limit, test time, frequency and open circuit no load voltage can all be pro-
grammed. The offset feature can automatically compensate for any lead resist-
ance.
1-800-253-1230
Fax 1-978-461-4295
Intl. 1-978-461-2100
For more information about special
purchase, rent & lease options, call
For more detailed
specifications, visit
www.quadtech.com
HIPOT TESTERS • LCR METERS • MEGOHMMETERS • MILLIOHMMETERS • CABLE TESTERS
6000 Series
Electrical Safety Analyzer
Page view 0
1 2

Summary of Contents

Page 1 - 6000 Series

GuardianUSES:• Production and Compliance Testing ofAppliances, Instruments and InformationTechnology Equipment in Accordancewith UL, CSA, IEC, TUV and

Page 2 - Product Specifications

AC Output Voltage: Range: 50V to 5000V AC, 1V resolutionFrequency: 50 or 60 Hz ProgrammableWaveform: SinusoidalRegulation: <(1% +5V) at Rated LoadV

Comments to this Manuals

No comments